The Exchange Modules netJACK run through a periodical system test. Usually this will be done with the release of a new product DVD, which contains firmware, device driver, configuration tool, auxiliary tools and documentation. The comprehensive tests will ensure an optimal interaction between all components and results in a fixed assignment between latest hardware, firmware, device driver, bootloader and configuration tool.

If you are using a different combination and you are facing problems, please contact your local distributor or Hilscher support.


Current release:

For previous versions see version history.


Configuration Tool

SYCON.net

Operating System Windows 2000Windows XP SP3Windows Vista SP2Windows 7Windows 8Windows 8.1Windows 10
Status(Fehler)(Fehler)(Haken)(Haken)(Haken)

(Haken)

(Haken)
Configuration Tool

netX Studio Engineering

Operating System Windows 2000Windows XP SP3Windows Vista SP2Windows 7Windows 8Windows 8.1Windows 10
Status(Fehler)(error)(error)(Haken)(Haken)

(Haken)

(Haken)
Device Driver

Device Driver Windows (NXDRV-WIN)

Operating SystemWindows XPWindows VistaWindows 7
(KB3033929)
Windows 8/8.1Windows 10Windows 10
(Desktop / Secure Boot)
Windows 10
 (Server)
Driver VersionV1.0.0.0V1.0.0.0V1.0.0.0V1.2.3.0V1.3.0.0V1.3.0.0- / -
Architecturex86x64x86x64x86x64x86x64x86x64x86x86x86
Status(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(tick)(tick)(error)


For other operting systems or toolkit follow the link.

NETJACK Hardware and Protocols

Host interface

CC-Link

CANopen

DeviceNet

PROFIBUS-DP

EtherCAT

EtherNet/IP

Modbus/TCP

POWERLINK

PROFINET IO

Sercos

VARAN


SPMDPMPCIeMasterSlaveMasterSlaveMasterSlaveMasterSlaveMasterSlaveScannerAdapterClient/ServerManaging
Node
Controlled
Node
ControllerDeviceMasterSlaveManagerClient

NJ 10D 1)

(Haken)(Haken)(Fehler)(Fehler)(Haken)(Fehler)(Haken)(Fehler)(Haken)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)
NJ 51D 1)(Haken)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Haken)(Fehler)(Haken)(Haken)(Fehler)(Haken)(Fehler)(Haken)(Fehler)(Haken)(Fehler)(Fehler)
NJ 100DN 1)(Fehler)(Haken)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Fehler)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Fehler)(Haken)(Haken)(Haken)(Haken)(Haken)(Fehler)(Haken)
NJ 100EN 2)(Fehler)(Fehler)(Haken)(Fehler)(Fehler)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Haken)(Fehler)(Haken)(Haken)(Haken)(Haken)(Haken)(Fehler)(Haken)

Legend

1) Host interface: Dual-port memory

2) Host Interface: PCI Express

NETJACK Product Features


Diagnostic interface
SYNC0/1

Slave
address
switch

Integrated 1)
Webserver
(servX)
Raw Ethernet (NDIS)6)

TCP socket
interface 6)




USBUART

CC-Link Slave

NJ 10x-CCS(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)(Fehler)(Fehler)
CANopen SlaveNJ 10x-COS(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)(Fehler)(Fehler)
DeviceNET SlaveNJ 10x-DNS(Haken)(Haken)(Fehler)
(Fehler)(Fehler)(Fehler)(Fehler)
PROFIBUS-DP SlaveNJ 10x-DPS(Haken)(Haken)(Fehler)
(Fehler)(Fehler)(Fehler)(Fehler)
EtherCAT SlaveNJ 51x-RE(Haken)(Haken)(Haken)(Fehler)
(Fehler)(Fehler)(Fehler)
EtherNet/IP AdapterNJ 51x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Haken)(Haken) 3)(Haken) 5)

Modbus/TCP Client/Server

NJ 51x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Haken)(Fehler)(Fehler)

POWERLINK Controlled Node

NJ 51x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)(Fehler)(Fehler)

PROFINET IO Device

NJ 51x-RE(Haken)(Haken)(Haken)(Fehler)
(Haken)(Haken) 3)(Haken) 5)

Sercos Slave

NJ 51x-RE(Haken)(Haken)(Haken)(Fehler)

(tick)

(Fehler)(Fehler)
EtherCAT MasterNJ 100x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)
(Fehler)(Fehler)
EtherCAT SlaveNJ 100x-RE(Haken)(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)(Fehler)
EtherNet/IP ScannerNJ 100x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Haken)(Fehler)(Fehler)
EtherNet/IP AdapterNJ 100x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Haken)(Fehler)(Fehler)
Modbus/TCP Client/ServerNJ 100x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Haken)(Fehler)(Fehler)
POWERLINK Controlled NodeNJ 100x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)
(Fehler)(Fehler)
PROFINET IO ControllerNJ 100x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)
(Fehler)(Fehler)
PROFINET IO DeviceNJ 100x-RE(Haken)(Haken)(Haken)(Fehler)
(Haken)(Fehler)(Fehler)
Sercos MasterNJ 100x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)
(Fehler)(Fehler)
Sercos SlaveNJ 100x-RE(Haken)(Haken)(Haken)(Fehler)
(tick)(Fehler)(Fehler)
VARAN ClientNJ 100x-RE(Haken)(Haken)(Fehler)
(Fehler)
(Fehler)
(Fehler)(Fehler)

Legend

1) If supported, the integrated WebServer is activated by default and can be deactivated via firmware TAG list.

2) Instead of NDIS EtherCAT supports EoE

3) The NDIS functionality is deactivated as default, but can be activated via Firmware TAG-List.
   Real-Time Ethernet will be offered to the host in Channel 0, NDIS and TCP socket in channel 1 and in IoT communication in channel 2.
   Channel 1 (NDIS and TCP socket interface) and Channel 2 (IOT communication) can only be accessed in SPM host interface mode. In DPM host interface mode only Channel 0 (RTE) can physically be adressed

4) LWIP TCP stack is used, which has a different API (socket API) than the Hilscher  TCP stack.

5) Hilscher  TCP stack is used, which has a different API (HIL TCP API) than LWIP TCP stack.

6) NDIS and TCP socket interface can only be accessed in SPM host interface mode, because only Channel 0 can be physically adressed in DPM mode.

7) OPC UA Server and MQTT Client can only be accessed in SPM host interface mode, because only Channel 0 can be physically adressed in DPM mode.


Documentation

Documentation about the products and tools can be found at:




  • No labels